<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-18 05-38-37
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 45 dBuV Classic
Pilot RDS Phase Difference
6.8 kHz 2.5 kHz 89 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 59 kHz 12261 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-1,0 dBr 1,14 dBr 2,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Sinfonia No.5 D-Duuri: IV os...(Mendelssohn Felix/Luther Martin)"
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 59 kHz MIN: 11 kHz % above 76 kHz: 0,0000 Acquired: 2025/12/18 5.37.32 Total samples: 12261 Equivalent time: 0:10:13 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 2,9 dBr MIN: -1,0 dBr AVE: 1,14 dBr % above 12,2 dBr: 0,0 Last value: 2,6 dBr (2025/12/18 5.37.31) 05.24 05.26 05.28 05.30 05.32 05.34 05.36 -1 0 1 2 3 Pm [dBr]